Portable Transit-Time Ultrasonic Flowmeter TF1100-EP
āļĢāļŦāļąāļŠāļŠāļīāļāļāđāļē : TF1100-EP
āļĢāļēāļāļē |
0.00 āļŋ |
āļāļģāļāļ§āļāļāļĩāđāļāļ°āļāļ·āđāļ | |
āļĢāļēāļāļēāļĢāļ§āļĄ | 0.00 āļŋ |
āļŠāļīāļāļāđāļēāđāļĄāđāđāļāļĩāļĒāļāļāļ
āļŠāļīāļāļāđāļēāļŦāļĄāļ
Portable Transit-Time Ultrasonic Flowmeter TF1100-EP
The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.
This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.
Featuresïž
1.50-hour battery (rechargeable), back-lit 4 lines display all integrated into a rugged, watertight enclosure.
2. Data logger function.
3. The heat measurement function by configuring with paired temperature sensors.
4. Non-invasive transducers.
5. Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35â~200â.
6. Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.
7. Lightweight and easily transportable in box.
Specifications: Transmitter
Measurement principle
- Ultrasonic transit-time difference correlation principle
Flow velocity range
- 0.01 to 12 m/s, bi-directional
Resolution
- 0.25mm/s
Repeatability
- 0.2% of reading
Accuracy
- Âą1.0% of reading at rates >0.3 m/s);Âą0.003 m/s of reading at rates<0.3 m/s
Response time
- 0.5s
Sensitivity
- 0.003m/s
Damping of displayed value
- 0-99s(selectable by user)
Liquid Types Supported
- both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply
- AC: 85-265V Up to 50 h with fully charged internal batteries
Enclosure type
- Portable
Degree of protection
- IP65 according to EN60529
Operating temperature
- -20â to +60â
Housing material
- ABS( UL 94HB)
Display
- 4 lineÃ16 English letters LCD graphic display, backlit
Units
- User Configured (English and Metric)
Rate
- Rate and Velocity Display
Totalized
- gallons, ftÂģ, barrels, lbs, liters, mÂģ,kg
Thermal energy
- unit GJ, KWh can be optional
Communication
- 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
Security
- Keypad lockout, system lockout
Size
- 270X215X175mm
Weight
- 3kgs
Specifications: Transducer
Degree of protection
- IP65 according to EN60529.(IP67 or IP68 Upon request)
Suited Liquid Temperature
- Std. Temp.: -35â~85â for short periods up to 120â
- High Temp.: -35â~200â for short periods up to 250â
Pipe diameter range
- 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Transducer Size
- Type S 52(h)*28(w)*26(d)mm
- Type M 60(h)*34(w)*32(d)mm
- Type L 80(h)*40(w)*42(d)mm
Material of transducer
- Aluminum for standard temp. sensor, and peek for high temp. sensor
Cable Length
- Std:5m
Temperature Sensor
- Pt1000, 0 to 200â, Clamp-on and Insertion type Accuracy: Âą0.1%